Madison, AL Certification

View PDF

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017, ANSI/NCSL Z540-1-1994 (R2002) AND ANSI/NCSL Z540.3-2006 (R2013)

Technical Maintenance, Inc.
117 Jetplex Circle, Suite C4
Madison, AL 35758
Scott Chamberlain Phone: 256-772-4115

CALIBRATION

Valid to: September 20, 2019 Certificate Number: AC-2080.02

Acoustics and Vibration

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
Accelerometers –

Acceleration

(7 to 200) Hz

(100 to 2 500) Hz

(2.5 to 10) kHz

(0.01 to 10) g 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

2.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

Accelerometer

Calibrator

Chemical Quantities

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
pH1 (4, 7, & 10) pH units 0.019 pH pH buffer solutions
Conductivity1 ≈100 µS

≈1 410 µS

≈10 000 µS

0.069 µS

5.1 µS

34 µS

Conductivity solutions



Version 004 Issued: November 1, 2017 www.anab.org

Page 1 of 14

Electrical – DC/Low Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
DC Voltage – Generate1 0 to 220 mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V

(220 to 1 100) V

11 µV/V + 0.4 µV

5.2 µV/V + 0.7 µV

3.5 µV/V + 2.5 µV

3.5 µV/V + 4 µV

5 µV/V + 40 µV

6.5 µV/V + 0.4 mV

Fluke 5730A
DC Voltage – Measure1 Up to 100 mV (0.1 to 1) V (1 to 10) V

(10 to 100) V (100 to 1 000) V

11 μV/V + 0.3 μV

10 μV/V + 0.3 μV

10 μV/V + 0.5 μV

12 μV/V + 30 μV

12 μV/V + 0.1 mV

HP 3458A
DC Voltage – Measure1 (1 to 30) kV (30 to 150) kV 0.13 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.12 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

Ross voltage dividers
DC Current – Generate1 Up to 220 µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A 40 µA/A + 6 nA

35 µA/A + 7 nA

36 µA/A + 40 nA

48 µA/A + 0.7 µA

81 µA/A + 12 µA

Fluke 5730A
DC Current – Generate1 (2.2 to 11) A (11 to 20.5) A 0.059 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.5 mA

0.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.75 mA

Fluke 5522A
DC Current – Measure1 Up to 100 nA (0.1to 100) µA

100 µA to 10 mA (10 to 100) mA (0.1 to 1) A

31 μA/A + 0.04 nA

22 μA/A + 0.8 nA

23 μA/A + 50 nA

37 μA/A + 0.5 μA

0.011 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 μA

HP 3458A
DC Current – Measure1 (1 to 600) A 0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading Current Shunts
Electrical Calibration of Thermocouple Indicating Devices1 – Type C

Type J Type K

Type N

Type R Type S

Type T

Type U

(0 to 2 316) °C

(-210 to 1 200) °C (-200 to 1 372) °C

(-200 to 1 300) °C

(0 to 1 767) °C

(-250 to 400) °C (-250 to 400) °C (-200 to 600) °C

0.38 °C

0.19 °C

0.21 °C

0.27 °C

0.45 °C

0.44 °C

0.18 °C

0.19 °C

Fluke 7526A

Version 004 Issued: November 1, 2017 www.anab.org

Page 2 of 14

Electrical – DC/Low Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
Power Meters1 3 µW to 100 mW 0.25 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading HP 11683A
Resistance – Generate, Fixed Points1 1, 1.9 Ω

10, 19 Ω

100, 190 Ω

1, 1.9 kΩ

10, 19 kΩ

100 kΩ

190 kΩ

1 MΩ

1.9 MΩ

10 MΩ

19 MΩ

100 MΩ

0.14 mΩ/Ω

33μΩ/Ω

35 μΩ/Ω

15 μΩ/Ω

13 μΩ/Ω

13 μΩ/Ω

15 μΩ/Ω

18 μΩ/Ω

25 μΩ/Ω

54 μΩ/Ω

66 μΩ/Ω

0.16 Ω/Ω

Fluke 5730A
Resistance – Generate1 Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω

330 Ω to 1.1 kΩ

(1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ

40 μΩ/Ω + 10 mΩ

30 μΩ/Ω + 15 mΩ

28 μΩ/Ω + 15 mΩ

28 μΩ/Ω + 0.02 Ω

29 μΩ/Ω + 0.02 Ω

29 μΩ/Ω + 0.2 Ω

29 μΩ/Ω + 0.1 Ω

29 μΩ/Ω + 1 Ω

29 μΩ/Ω + 1 Ω

Fluke 5520A
Resistance – Measure1 Up to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ

(10 to 100) kΩ

(0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ

16 μΩ/Ω + 50 μΩ

14 μΩ/Ω + 0.5 mΩ

12 μΩ/Ω + 0.5 mΩ

12 μΩ/Ω + 5 mΩ

12 μΩ/Ω + 5 mΩ

16 μΩ/Ω + 2.0 Ω

50 μΩ/Ω + 0.1 kΩ

0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 1 kΩ

0.51 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 kΩ

HP 3458A

Version 004 Issued: November 1, 2017 www.anab.org

Page 3 of 14

Electrical – DC/Low Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
AC Voltage – Generatev (0.22 to 2.2) mV

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 20 kHz

(20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz

500 kHz to 1 MHz

(2.2 to 22) mV

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz

500 kHz to 1 MHz

(22 to 220) mV

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz

500 kHz to 1 MHz

(0.22 to 2.2) V

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 20 kHz

(20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz

500 kHz to 1 MHz

0.36 mV/V + 5 µV

0.12 mV/V + 4 µV

0.11 mV/V + 4 µV

0.24 mV/V + 4 µV

0.6 mV/V + 5 µV

1.3 mV/V + 10 µV

1.7 mV/V + 20 µV

3.2 mV/V + 20 µV

0.36 mV/V + 5 µV

0.12 mV/V + 4 µV

0.11 mV/V + 4 µV

0.24 mV/V + 4 µV

0.6 mV/V + 5 µV

1.3 mV/V + 10 µV

1.7 mV/V + 20 µV

3.2 mV/V + 20 µV

0.24 mV/V + 12 µV

0.11 mV/V + 7 µV

69 µV/V + 7 µV

0.14 mV/V + 7 µV

0.37 mV/V + 17 µV

0.77 mV/V + 20 µV

1.7 mV /V + 25 µV

3.2 mV /V + 45 µV

0.28 mV/V + 40 µV

0.11 mV/V + 15 µV

50 µV/V + 8 µV

78 µV/V + 10 µV

0.1 mV/V + 30 µV

0.4 mV/V + 80 µV

1.2 mV /V + 0.2 mV

0.2 mV/V + 0.3 mV

Fluke 5730A

Version 004 Issued: November 1, 2017 www.anab.org

Page 4 of 14

Electrical – DC/Low Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
AC Voltage – Generate1 (2.2 to 22) V

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 20 kHz

(20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz

500 kHz to 1 MHz

(22 to 220) V

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz

500 kHz to 1 MHz

0.28 mV/V + 0.4 mV

0.11 mV/V + 0.15 mV

50 µV/V + 50 µV

78 µV/V + 0.1 mV

98 µV/V + 0.2 mV

0.3 mV/V + 0.6 mV

1.2 mV/V + 2 mV

1.8 mV/V + 3.2 mV

0.28 mV/V + 4 mV

0.11 mV/V + 1.5 mV

62 µV/V + 0.6 mV

93 µV/V + 1 mV

0.18 mV/V + 2.5 mV

1.1 mV/V + 16 mV

5.1 mV/V + 40 mV

9.3 mV/V + 80 mV

Fluke 5730A
AC Voltage – Generate1 (220 to 750) V

(30 to 50) kHz

(50 to 100) kHz

(750 to 1 000) V

40 Hz to 1 kHz

(1 to 20) kHz

(20 to 30) kHz

0.7 mV/V + 11 mV

2.7 mV/V + 45 mV

0.11 mV/V + 4 mV

0.2 mV/V + 6 mV

0.7 mV/V + 11 mV

Fluke 5730A/5725A
AC Voltage – Measure1 Up to 10 mV

(1 to 40) Hz

40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz

(100 to 300) kHz

0.044 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.003 mV

0.026 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV

0.044 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV

0.11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV

0.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV

4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV

HP 3458A

Version 004 Issued: November 1, 2017 www.anab.org

Page 5 of 14

AC Voltage – Measure1 10 mV to 100 mV (1 to 40) Hz

40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz

(50 to 100) kHz

(100 to 300) kHz

300 kHz to 1 MHz

(1 to 2) MHz

100 mV to 1 V

(1 to 40) Hz

40 Hz to 1 kHz

(1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz

300 kHz to 1 MHz

(1 to 2) MHz

1 V to 10 V

(1 to 40) Hz

40 Hz to 1 kHz

(1 to 20) kHz

(20 to 50) kHz (50 to 100) kHz (100 to 300) kHz

300 kHz to 1 MHz

(1 to 2) MHz

(10 to 100) V

(1 to 40) Hz

40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz

(100 to 300) kHz

300 kHz to 1 MHz

(100 to 700) V

(1 to 40) Hz

40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz

0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.004 mV

0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV

0.027 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV

0.045 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV

0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV

0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 mV

1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 mV

1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 mV

0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.04 mV

0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV

0.027 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV

0.045 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV

0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV

0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV

1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV

1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV

0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0004 V

0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V

0.027 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V

0.045 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V

0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V

0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.001 V

1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.001 V

1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.001 V

0.026 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V

0.041 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V

0.038 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V

0.048 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V

0.13 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V

0.4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 V

1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 V

0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.04 V

0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V

0.07 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V

0.13 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V

0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V

HP 3458A
AC Voltage – Measure1 (1 to 21) kV

Up to 400 Hz

(21 to 100) kV

Up to 400 Hz

0.59 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.62 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

Ross voltage dividers



Version 004 Issued: November 1, 2017 www.anab.org

Page 6 of 14

Electrical – DC/Low Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
AC Current – Generate1 (9 to 220) µA

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

(0.22 to 2.2) mA

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

(2.2 to 22) mA

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

(22 to 220) mA

(10 to 20) Hz

(20 to 40) Hz

40 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

(0.22 to 2.2) A

20 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

0.31 mA/A + 16 nA

0.21 mA/A + 10 nA

0.15 mA/A + 8 nA

0.35 mA/A + 12 nA

1.3 mA/A + 65 nA

0.3 mA/A + 40 nA

0.16 mA/A + 35 nA

0.14 mA/A + 35 nA

0.25 mA/A + 0.11 µA

1.3 mA/A + 0.65 µA

0.31 mA/A + 0.4 µA

0.2 mA/A + 0.35 µA

0.14 mA/A + 0.35 µA

0.26 mA/A + 0.55 µA

1.4 mA/A + 5 µA

0.3 mA/A + 4 µA

0.2 mA/A + 3.5 µA

0.14 mA/A + 2.5 µA

0.26 mA/A + 3.5 µA

1.4 mA/A + 10 µA

0.3 mA/A + 35 µA

0.54 mA/A + 80 µA

8.2 mA/A + 0.16 mA

Fluke 5730A
AC Current – Generate1 (2.2 to 11) A

40 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

0.56 mA/A + 0.17 mA

1.2 mA/A + 0.38 mA

4.3 mA/A + 0.75 mA

Fluke 5730A/5725A
AC Current – Generate1 (11 to 20.5) A

45 Hz to 100 Hz

100 Hz to 1 kHz

(1 to 5) kHz

0.19 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA

0.24 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA

4.6 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA

Fluke 5522A

Version 004 Issued: November 1, 2017 www.anab.org

Page 7 of 14

Electrical – DC/Low Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
AC Current – Measure1 Up to 100 μA

(10 to 20) Hz

(20 to 45) Hz

45 Hz to 1 kHz

(1 to 100) mA

(10 to 20) Hz

(20 to 45) Hz

(45 to 100) Hz

100 Hz to 5 kHz

(5 to 20) kHz (20 to 50) kHz (50 to 100) kHz

(0.1 to 1) A

(10 to 20) Hz

(20 to 45) Hz

(45 to 100) Hz

100 Hz to 5 Hz

(5 to 20) kHz

(20 to 50) kHz

0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA

0.16 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA

0.07 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA

0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA

0.16 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA

0.069 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA

0.038 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA

0.069 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA

0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 40 μA

0.56 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.15 mA

0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA

0.17 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA

0.087 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA

0.11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA

0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA

1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.4 mA

HP 3458A
AC Current – Measure1 (1 to 600) A

30 Hz to 10 kHz

3.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading Current Clamp
Capacitance1 – Generate

10 Hz to 10 kHz

10 Hz to 3 kHz

10 Hz to 1 kHz

(10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz

(0 to 20) Hz

(0 to 6) Hz

(0 to 2) Hz

(0 to 0.6) Hz

(0 to 0.2) Hz

(0.19 to 0.1099) nF (1.1 to 3.2999) nF (3.3 to 329.999) nF (0.33 to 1.09999) µF (1.1 to 3.29999) µF (3.3 to 10.9999) µF (11 to 32.999) µF

(33 to 109.999) µF (110 to 329.999) µF

(0.33 to 1.09999) mF

(1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF

1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 nF

1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 nF

0.39 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.3 nF

0.38 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 nF

0.37 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 nF

0.38 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 nF

0.53 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 30 nF

0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 µF

0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.3 µF

0.57 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 1 μF

0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 μF

0.59 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 μF

0.65 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 30 μF

1.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mF

Fluke 5522A

Version 004 Issued: November 1, 2017 www.anab.org

Page 8 of 14

Electrical – DC/Low Frequency

Electrical – RF/Microwave

Version 004 Issued: November 1, 2017 www.anab.org

Page 9 of 14

Electrical – RF/Microwave

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
RF Attenuation1– Measure 100 kHz to 31.15 GHz

(-100 to -91) dB

100 kHz to 26.5 GHz

(-110 to -101) dB (-120 to -111) dB

0.074 dB

0.086 dB

0.091 dB

Agilent N5531S
RF Power1 – Measure

50 MHz

1 mW 0.003 2 mW HP 432A & 8478B
RF Power – Generate 250 kHz to 20 GHz

(-10 to 10) dBm

(-70 to -10) dBm

(-90 to -70) dBm

(20 to 50) GHz

(-10 to 10) dBm (-70 to -10) dBm (-90 to -70) dBm

1.5 dBm

1.6 dBm

1.7 dBm

1.6 dBm

1.7 dBm

2.6 dBm

Agilent E8257D
Amplitude

Modulation1 – Measure

100 kHz to 10 MHz

(5 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

10 MHz to 3 GHz

(5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(3 to 26.5) GHz

(5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(26.5 to 31.5) GHz

(5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(31.5 to 50) GHz

(5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

(20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

2.9 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

0.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

5.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

1.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

7.9 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

2.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

30 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

7 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth

Agilent N5531S
Frequency Modulation1 – Measure 20 Hz to 10 kHz

250 kHz to 10 MHz

(50 to 200) Hz

10 MHz to 6.6 GHz

(6.6 to 13.2) GHz

(13.2 to 31.15) GHz

(31.15 to 50) GHz

3.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

3.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

3.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

Agilent N5531S
Phase Modulation1 – Measure 100 kHz to 50 GHz 9.7 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading Agilent N5531S

Version 004 Issued: November 1, 2017 www.anab.org

Page 10 of 14

Electrical – RF/Microwave

Length – Dimensional metrology

Version 004 Issued: November 1, 2017 www.anab.org

Page 11 of 14

Length – Dimensional metrology

Mass

Version 004 Issued: November 1, 2017 www.anab.org

Page 12 of 14

Mass

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
Torque Wrenches1 (5 to 1 000) lbf⋅in (25 to 250) lbf⋅ft (250 to 2 000) lbf⋅ft 0.35 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.43 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.49 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

CDI torque system
Torque Analyzers (5 to 80) ozf⋅in (5 to 600) lbf⋅in (50 to 2 000) lbf⋅ft 0.17 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.15 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.14 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

Weights and Wheel
Mass (1 to 10) lb 0.048 g Master balance
Force – Tension1 (10 to 200) mgrf

(0.2 to 1) grf

(1 to 10) grf (10 to 500) grf (1 to 540) lbf

0.63 mgrf

1 mgrf

0.038 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.025 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

0.026 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading

Class F weights

Thermodynamic

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
Temperature – Measuring

Equipment1

(50 to 600) °C 0.11 °C Hart 1502A w/5626

PRT and dry block

Temperature – Measure1 (-25 to 600) °C 0.026 °C Hart 1502 with 5626 PRT
Relative Humidity – Measure1 (0 to 90) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} RH 1.6 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}RH Vaisalla

HM141/HMP46

IR Thermometry1 (20 to 100) °C (100 to 300) °C (300 to 500) °C 0.51 °C

0.61 °C

0.8 °C

Fluke 9132

Time and Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
Frequency – Measure1 10 MHz 1 part in 1011 Hz/Hz GPS 58503A/B
Frequency – Measure1 10 Hz to 500 MHz 5 parts in 107 Hz/Hz HP 5345A

Version 004 Issued: November 1, 2017 www.anab.org

Page 13 of 14

Time and Frequency

Parameter/Equipment Range Expanded Uncertainty of

Measurement (+/-)

Reference Standard, Method, and/or Equipment
Frequency – Measure1 500 MHz to 26.5 GHz

(26.5 to 40) GHz

1.7 parts in 109 Hz/Hz

1 parts in 107 Hz/Hz

HP 5343A

 

Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95{3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}.

Notes:

1. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement uncertainties are expected on-site than what is reported on the accredited scope.

2. L = length in inches, D = diameter in inches, t = time in seconds, R = resolution of device under test.

3. This scope is formatted as part of a single document including Certificate of Accreditation No. AC-2080.02.



Version 004 Issued: November 1, 2017 www.anab.org

Page 14 of 14