SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017, ANSI/NCSL Z540-1-1994 (R2002) AND ANSI/NCSL Z540.3-2006 (R2013)
Technical Maintenance, Inc.
117 Jetplex Circle, Suite C4
Madison, AL 35758
Scott Chamberlain Phone: 256-772-4115
CALIBRATION
Valid to: September 20, 2019 Certificate Number: AC-2080.02
Acoustics and Vibration
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Accelerometers –
Acceleration (7 to 200) Hz (100 to 2 500) Hz (2.5 to 10) kHz |
(0.01 to 10) g | 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading
1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 2.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
Accelerometer
Calibrator |
Chemical Quantities
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
pH1 | (4, 7, & 10) pH units | 0.019 pH | pH buffer solutions |
Conductivity1 | ≈100 µS
≈1 410 µS ≈10 000 µS |
0.069 µS
5.1 µS 34 µS |
Conductivity solutions |
Version 004 Issued: November 1, 2017 www.anab.org
Page 1 of 14
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
DC Voltage – Generate1 | 0 to 220 mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V
(220 to 1 100) V |
11 µV/V + 0.4 µV
5.2 µV/V + 0.7 µV 3.5 µV/V + 2.5 µV 3.5 µV/V + 4 µV 5 µV/V + 40 µV 6.5 µV/V + 0.4 mV |
Fluke 5730A |
DC Voltage – Measure1 | Up to 100 mV (0.1 to 1) V (1 to 10) V
(10 to 100) V (100 to 1 000) V |
11 μV/V + 0.3 μV
10 μV/V + 0.3 μV 10 μV/V + 0.5 μV 12 μV/V + 30 μV 12 μV/V + 0.1 mV |
HP 3458A |
DC Voltage – Measure1 | (1 to 30) kV (30 to 150) kV | 0.13 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading
0.12 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
Ross voltage dividers |
DC Current – Generate1 | Up to 220 µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A | 40 µA/A + 6 nA
35 µA/A + 7 nA 36 µA/A + 40 nA 48 µA/A + 0.7 µA 81 µA/A + 12 µA |
Fluke 5730A |
DC Current – Generate1 | (2.2 to 11) A (11 to 20.5) A | 0.059 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.5 mA
0.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.75 mA |
Fluke 5522A |
DC Current – Measure1 | Up to 100 nA (0.1to 100) µA
100 µA to 10 mA (10 to 100) mA (0.1 to 1) A |
31 μA/A + 0.04 nA
22 μA/A + 0.8 nA 23 μA/A + 50 nA 37 μA/A + 0.5 μA 0.011 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 μA |
HP 3458A |
DC Current – Measure1 | (1 to 600) A | 0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Current Shunts |
Electrical Calibration of Thermocouple Indicating Devices1 – Type C
Type J Type K Type N Type R Type S Type T Type U |
(0 to 2 316) °C
(-210 to 1 200) °C (-200 to 1 372) °C (-200 to 1 300) °C (0 to 1 767) °C (-250 to 400) °C (-250 to 400) °C (-200 to 600) °C |
0.38 °C
0.19 °C 0.21 °C 0.27 °C 0.45 °C 0.44 °C 0.18 °C 0.19 °C |
Fluke 7526A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 2 of 14
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Power Meters1 | 3 µW to 100 mW | 0.25 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | HP 11683A |
Resistance – Generate, Fixed Points1 | 1, 1.9 Ω
10, 19 Ω 100, 190 Ω 1, 1.9 kΩ 10, 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ |
0.14 mΩ/Ω
33μΩ/Ω 35 μΩ/Ω 15 μΩ/Ω 13 μΩ/Ω 13 μΩ/Ω 15 μΩ/Ω 18 μΩ/Ω 25 μΩ/Ω 54 μΩ/Ω 66 μΩ/Ω 0.16 Ω/Ω |
Fluke 5730A |
Resistance – Generate1 | Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω
330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ |
40 μΩ/Ω + 10 mΩ
30 μΩ/Ω + 15 mΩ 28 μΩ/Ω + 15 mΩ 28 μΩ/Ω + 0.02 Ω 29 μΩ/Ω + 0.02 Ω 29 μΩ/Ω + 0.2 Ω 29 μΩ/Ω + 0.1 Ω 29 μΩ/Ω + 1 Ω 29 μΩ/Ω + 1 Ω |
Fluke 5520A |
Resistance – Measure1 | Up to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ
(10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ |
16 μΩ/Ω + 50 μΩ
14 μΩ/Ω + 0.5 mΩ 12 μΩ/Ω + 0.5 mΩ 12 μΩ/Ω + 5 mΩ 12 μΩ/Ω + 5 mΩ 16 μΩ/Ω + 2.0 Ω 50 μΩ/Ω + 0.1 kΩ 0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 1 kΩ 0.51 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 kΩ |
HP 3458A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 3 of 14
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Voltage – Generatev | (0.22 to 2.2) mV
(10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (2.2 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (22 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (0.22 to 2.2) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz |
0.36 mV/V + 5 µV
0.12 mV/V + 4 µV 0.11 mV/V + 4 µV 0.24 mV/V + 4 µV 0.6 mV/V + 5 µV 1.3 mV/V + 10 µV 1.7 mV/V + 20 µV 3.2 mV/V + 20 µV 0.36 mV/V + 5 µV 0.12 mV/V + 4 µV 0.11 mV/V + 4 µV 0.24 mV/V + 4 µV 0.6 mV/V + 5 µV 1.3 mV/V + 10 µV 1.7 mV/V + 20 µV 3.2 mV/V + 20 µV 0.24 mV/V + 12 µV 0.11 mV/V + 7 µV 69 µV/V + 7 µV 0.14 mV/V + 7 µV 0.37 mV/V + 17 µV 0.77 mV/V + 20 µV 1.7 mV /V + 25 µV 3.2 mV /V + 45 µV 0.28 mV/V + 40 µV 0.11 mV/V + 15 µV 50 µV/V + 8 µV 78 µV/V + 10 µV 0.1 mV/V + 30 µV 0.4 mV/V + 80 µV 1.2 mV /V + 0.2 mV 0.2 mV/V + 0.3 mV |
Fluke 5730A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 4 of 14
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Voltage – Generate1 | (2.2 to 22) V
(10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (22 to 220) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz |
0.28 mV/V + 0.4 mV
0.11 mV/V + 0.15 mV 50 µV/V + 50 µV 78 µV/V + 0.1 mV 98 µV/V + 0.2 mV 0.3 mV/V + 0.6 mV 1.2 mV/V + 2 mV 1.8 mV/V + 3.2 mV 0.28 mV/V + 4 mV 0.11 mV/V + 1.5 mV 62 µV/V + 0.6 mV 93 µV/V + 1 mV 0.18 mV/V + 2.5 mV 1.1 mV/V + 16 mV 5.1 mV/V + 40 mV 9.3 mV/V + 80 mV |
Fluke 5730A |
AC Voltage – Generate1 | (220 to 750) V
(30 to 50) kHz (50 to 100) kHz (750 to 1 000) V 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz |
0.7 mV/V + 11 mV
2.7 mV/V + 45 mV 0.11 mV/V + 4 mV 0.2 mV/V + 6 mV 0.7 mV/V + 11 mV |
Fluke 5730A/5725A |
AC Voltage – Measure1 | Up to 10 mV
(1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz |
0.044 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.003 mV
0.026 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV 0.044 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV 0.11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV 0.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0011 mV 4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV |
HP 3458A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 5 of 14
AC Voltage – Measure1 | 10 mV to 100 mV (1 to 40) Hz
40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz 100 mV to 1 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz 1 V to 10 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (10 to 100) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (100 to 700) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz |
0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.004 mV
0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV 0.027 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV 0.045 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV 0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 mV 0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 mV 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 mV 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 mV 0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.04 mV 0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV 0.027 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV 0.045 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV 0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 mV 0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV 0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0004 V 0.019 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V 0.027 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V 0.045 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V 0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.0002 V 0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.001 V 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.001 V 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.001 V 0.026 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V 0.041 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V 0.038 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V 0.048 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V 0.13 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 V 0.4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 V 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 V 0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.04 V 0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V 0.07 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V 0.13 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V 0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 V |
HP 3458A |
AC Voltage – Measure1 | (1 to 21) kV
Up to 400 Hz (21 to 100) kV Up to 400 Hz |
0.59 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading
0.62 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
Ross voltage dividers |
Version 004 Issued: November 1, 2017 www.anab.org
Page 6 of 14
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Current – Generate1 | (9 to 220) µA
(10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (0.22 to 2.2) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (2.2 to 22) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (0.22 to 2.2) A 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz |
0.31 mA/A + 16 nA
0.21 mA/A + 10 nA 0.15 mA/A + 8 nA 0.35 mA/A + 12 nA 1.3 mA/A + 65 nA 0.3 mA/A + 40 nA 0.16 mA/A + 35 nA 0.14 mA/A + 35 nA 0.25 mA/A + 0.11 µA 1.3 mA/A + 0.65 µA 0.31 mA/A + 0.4 µA 0.2 mA/A + 0.35 µA 0.14 mA/A + 0.35 µA 0.26 mA/A + 0.55 µA 1.4 mA/A + 5 µA 0.3 mA/A + 4 µA 0.2 mA/A + 3.5 µA 0.14 mA/A + 2.5 µA 0.26 mA/A + 3.5 µA 1.4 mA/A + 10 µA 0.3 mA/A + 35 µA 0.54 mA/A + 80 µA 8.2 mA/A + 0.16 mA |
Fluke 5730A |
AC Current – Generate1 | (2.2 to 11) A
40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz |
0.56 mA/A + 0.17 mA
1.2 mA/A + 0.38 mA 4.3 mA/A + 0.75 mA |
Fluke 5730A/5725A |
AC Current – Generate1 | (11 to 20.5) A
45 Hz to 100 Hz 100 Hz to 1 kHz (1 to 5) kHz |
0.19 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA
0.24 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA 4.6 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA |
Fluke 5522A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 7 of 14
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Current – Measure1 | Up to 100 μA
(10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 100) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 Hz (5 to 20) kHz (20 to 50) kHz |
0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA
0.16 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA 0.07 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA 0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.16 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.069 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.038 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.069 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 40 μA 0.56 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.15 mA 0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.17 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.087 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.4 mA |
HP 3458A |
AC Current – Measure1 | (1 to 600) A
30 Hz to 10 kHz |
3.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Current Clamp |
Capacitance1 – Generate
10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz |
(0.19 to 0.1099) nF (1.1 to 3.2999) nF (3.3 to 329.999) nF (0.33 to 1.09999) µF (1.1 to 3.29999) µF (3.3 to 10.9999) µF (11 to 32.999) µF
(33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.09999) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF |
1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 nF
1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 nF 0.39 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.3 nF 0.38 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 nF 0.37 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 nF 0.38 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 nF 0.53 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 30 nF 0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 µF 0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.3 µF 0.57 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 1 μF 0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 μF 0.59 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 μF 0.65 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 30 μF 1.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mF |
Fluke 5522A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 8 of 14
Electrical – DC/Low Frequency
Electrical – RF/Microwave
Version 004 Issued: November 1, 2017 www.anab.org
Page 9 of 14
Electrical – RF/Microwave
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
RF Attenuation1– Measure | 100 kHz to 31.15 GHz
(-100 to -91) dB 100 kHz to 26.5 GHz (-110 to -101) dB (-120 to -111) dB |
0.074 dB
0.086 dB 0.091 dB |
Agilent N5531S |
RF Power1 – Measure
50 MHz |
1 mW | 0.003 2 mW | HP 432A & 8478B |
RF Power – Generate | 250 kHz to 20 GHz
(-10 to 10) dBm (-70 to -10) dBm (-90 to -70) dBm (20 to 50) GHz (-10 to 10) dBm (-70 to -10) dBm (-90 to -70) dBm |
1.5 dBm
1.6 dBm 1.7 dBm 1.6 dBm 1.7 dBm 2.6 dBm |
Agilent E8257D |
Amplitude
Modulation1 – Measure |
100 kHz to 10 MHz
(5 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 10 MHz to 3 GHz (5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (3 to 26.5) GHz (5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (26.5 to 31.5) GHz (5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (31.5 to 50) GHz (5 to 20) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth (20 to 99) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth |
1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth
2.9 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 0.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 5.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 1.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 7.9 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 2.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 30 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth 7 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} Depth |
Agilent N5531S |
Frequency Modulation1 – Measure | 20 Hz to 10 kHz
250 kHz to 10 MHz (50 to 200) Hz 10 MHz to 6.6 GHz (6.6 to 13.2) GHz (13.2 to 31.15) GHz (31.15 to 50) GHz |
3.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading
3.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 3.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
Agilent N5531S |
Phase Modulation1 – Measure | 100 kHz to 50 GHz | 9.7 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Agilent N5531S |
Version 004 Issued: November 1, 2017 www.anab.org
Page 10 of 14
Electrical – RF/Microwave
Length – Dimensional metrology
Version 004 Issued: November 1, 2017 www.anab.org
Page 11 of 14
Length – Dimensional metrology
Mass
Version 004 Issued: November 1, 2017 www.anab.org
Page 12 of 14
Mass
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Torque Wrenches1 | (5 to 1 000) lbf⋅in (25 to 250) lbf⋅ft (250 to 2 000) lbf⋅ft | 0.35 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading
0.43 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 0.49 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
CDI torque system |
Torque Analyzers | (5 to 80) ozf⋅in (5 to 600) lbf⋅in (50 to 2 000) lbf⋅ft | 0.17 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading
0.15 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 0.14 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
Weights and Wheel |
Mass | (1 to 10) lb | 0.048 g | Master balance |
Force – Tension1 | (10 to 200) mgrf
(0.2 to 1) grf (1 to 10) grf (10 to 500) grf (1 to 540) lbf |
0.63 mgrf
1 mgrf 0.038 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 0.025 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading 0.026 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading |
Class F weights |
Thermodynamic
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Temperature – Measuring
Equipment1 |
(50 to 600) °C | 0.11 °C | Hart 1502A w/5626
PRT and dry block |
Temperature – Measure1 | (-25 to 600) °C | 0.026 °C | Hart 1502 with 5626 PRT |
Relative Humidity – Measure1 | (0 to 90) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} RH | 1.6 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}RH | Vaisalla
HM141/HMP46 |
IR Thermometry1 | (20 to 100) °C (100 to 300) °C (300 to 500) °C | 0.51 °C
0.61 °C 0.8 °C |
Fluke 9132 |
Time and Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Frequency – Measure1 | 10 MHz | 1 part in 1011 Hz/Hz | GPS 58503A/B |
Frequency – Measure1 | 10 Hz to 500 MHz | 5 parts in 107 Hz/Hz | HP 5345A |
Version 004 Issued: November 1, 2017 www.anab.org
Page 13 of 14
Time and Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Frequency – Measure1 | 500 MHz to 26.5 GHz
(26.5 to 40) GHz |
1.7 parts in 109 Hz/Hz
1 parts in 107 Hz/Hz |
HP 5343A |
Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95{3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}.
Notes:
1. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement uncertainties are expected on-site than what is reported on the accredited scope.
2. L = length in inches, D = diameter in inches, t = time in seconds, R = resolution of device under test.
3. This scope is formatted as part of a single document including Certificate of Accreditation No. AC-2080.02.
Version 004 Issued: November 1, 2017 www.anab.org