SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017, ANSI/NCSL Z540-1-1994 (R2002) AND ANSI/NCSL Z540.3-2006 (R2013)
Technical Maintenance, Inc.
3060 Venture Lane
Melbourne, FL 32934
Scott Chamberlain 321-242-0890
CALIBRATION
Valid to: September 20, 2019 Certificate Number: AC-2080.08
Chemical Quantities
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
pH1 | (4, 7, 10) pH | 0.02 pH | pH buffer solutions |
Conductivity, Liquid1 | (2 to 10 000) µS | 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Conductivity solutions |
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
DC Current – Generate1 | Up to 220 µA
220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A |
40 µA/A + 6 nA
35 µA/A + 7 nA 36 µA/A + 40 nA 48 µA/A + 0.7 µA 81 µA/A + 12 µA |
Fluke 5730A/03
Multifunction Calibrator |
DC Current – Generate1 | (2.2 to 11) A | 0.36 mA/A + 0.48 mA | Fluke 5730A/03
Multifunction Calibrator 5725A Amplifier |
DC Current – Generate1 | (11 to 20.5) A | 0.76 mA/A + 0.75 mA | Fluke 5522A Multifunction Calibrator |
DC Current – Generate1
Clamp Only |
(20.5 to 1 000) A | 0.9 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Coil/ Fluke 5522A Multifunction Calibrator |
Version 004 Issued: November 10, 2017 www.anab.org
Page 1 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
DC Current – Measure1 | Up to 220 µA
220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA (0.22 to 1) A |
6 µA/A
5 µA/A 6 µA/A 10 µA/A 37 µA/A |
Agilent 3458A/002
Precision Multimeter |
DC Voltage1 – Generate | (0 to 220) mV
220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1 100) V |
11 µV/V + 0.4 µV
5.2 µV/V + 0.7 µV 3.5 µV/V + 2.5 µV 3.5 µV/V + 4 µV 5 µV/V + 40 µV 6.5 µV/V + 400 µV |
Fluke 5730A/03
Multifunction Calibrator |
DC Voltage1 – Measure | Up to 100 mV (0.1 to 1) V (1 to 10) V
(10 to 100) V (100 to 1 000) V |
10 µV/V + 0.3 µV
9.0 µV/V + 0.30 µV 9.0 µV/V + 50 µV 11 µV/V + 30 µV 11 µV/V + 0.1 mV |
Agilent 3458A/002
Precision Multimeter |
DC Voltage1 – Measure | (1 to 120) kV | 0.23 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Ross VD120 High
Voltage Divider HP 34401A Precision Multimeter |
AC Voltage – Generate1 | (0.22 to 2.2) mV
(10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (2.2 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz |
0.27 mV/V + 4 µV
0.14 mV/V + 4 µV 0.13 mV/V + 4 µV 0.22 mV/V + 4 µV 0.52 mV/V + 5 µV 1. 1 mV/V + 10 µV 1.4 mV/V + 20 µV 2.7 mV/V + 20 µV 0.24 mV/V + 4 µV 91 µV/V + 4 µV 81 µV/V + 4 µV 0.2 mV/V + 4 µV 0.5 mV/V + 5 µV 1.1 mV/V + 10 µV 1.4 mV/V + 20 µV 2.7 mV/V + 20 µV |
Fluke 5730A/03
Multifunction Calibrator |
Version 004 Issued: November 10, 2017 www.anab.org
Page 2 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Voltage – Generate1 | (22 to 220) mV
(10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 220 mV to 2.2 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (22 to 220) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (220 to 750) V 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz |
0.24 mV/V + 12 µV
90 µV/V + 7 µV 58 µV/V + 7 µV 0.12 mV/V + 7 µV 0.31 mV/V + 17 µV 0.66 mV/V + 20 µV 1.4 mV /V + 25 µV 2.7 mV /V + 45 µV 0.24 mV/V + 40 µV 90 µV/V + 15 µV 43 µV/V + 8 µV 67 µV/V + 10 µV 85 µV/V + 30 µV 0.34 mV/V + 80 µV 1 mV /V + 0.2 mV 1.7 mV/V + 0.3 mV 0.24 mV/V + 0.4 mV 91 µV/V + 0.15 mV 43 µV/V + 50 µV 67 µV/V + 0.1 mV 83 µV/V + 0.2 mV 0.25 mV/V + 0.6 mV 1 mV/V + 2 mV 1 5 mV/V + 3.2 mV 0.24 mV /V + 4 mV 90 µV/V + 1.5 mV 52 µV/V + 0.6 mV 80 µV/V + 1 mV 0.15 mV /V + 2.5 mV 91 µV/V + 4 mV 0.17 mV /V + 6 mV 0.6 mV /V + 11 mV 2 3 mV /V + 45 mV |
Fluke 5730A/03
Multifunction Calibrator |
Version 004 Issued: November 10, 2017 www.anab.org
Page 3 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Voltage – Generate1 | (750 to 1 000) V
40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz |
91 µV/V + 4 mV
0.17 mV /V + 6 mV 0.6 mV /V + 11 mV |
Fluke 5730A/03
Multifunction Calibrator 5725A Amplifier |
AC Voltage – Measure1 | Up to 10 mV
(1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 10 mV to 10 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (10 to 100) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz |
0.03 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range
0.02 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.011 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.03 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.011 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.011 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.011 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.02 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.007 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.004 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.007 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.014 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.03 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.02 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.004 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.02 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.02 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.04 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.12 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range |
Agilent 3458A/002
Precision Multimeter |
AC Voltage – Measure1 | (100 to 1 000) V
(1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz |
0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.004 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range
0.04 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.06 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.12 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range 0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.002 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of range |
Agilent 3458A/002
Precision Multimeter |
AC Voltage – Measure1 | (1 to 85) kV
(50, 60) Hz |
0.7 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Ross VD120 High
Voltage Divider HP 34401A Precision Multimeter |
Version 004 Issued: November 10, 2017 www.anab.org
Page 4 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Current – Generate1 | (9 to 220) µA
(10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz |
0.25 mA/A + 16 nA
0.16 mA /A + 10 nA 0.1 mA /A + 8 nA 0.28 mA /A + 12 nA 1.1 mA /A + 65 nA |
Fluke 5730A/03
Multifunction Calibrator |
AC Current – Generate1 | (0.22 to 2.2) mA
(10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (2.2 to 22) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz 1 to 5 kHz (5 to 10) kHz (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz |
0.25 mA /A + 40 nA
0.16 mA /A + 35 nA 0.1 mA /A + 35 nA 0.2 mA /A + 0.110 µA 1.1 mA /A + 0.650 µA 0.25 mA /A + 0.4 µA 0.16 mA /A + 0.35 µA 0.1 mA /A + 0.35 µA 0.2 mA /A + 0.55 µA 1.1 mA /A + 5 µA 0.25 mA /A + 4 µA 0.16 mA /A + 3.5 µA 0.1 mA /A + 2.5 µA 0.2 mA /A + 3.5 µA 1.1 mA /A + 10 µA |
Fluke 5730A/03
Multifunction Calibrator |
AC Current – Generate1 | (0.22 A to 2.2) A
20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz |
0.25 mA/A + 35 µA
0.45 mA /A + 80 µA 7 mA /A + 0.16 mA |
Fluke 5730A/03
Multifunction Calibrator 5725A Amplifier |
AC Current – Generate1 | (2.2 to 11) A
40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (11 to 20.5) A (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz |
0.46 mA /A + 0.17 mA
0.95 mA /A + 0.38 mA 3.6 mA /A + 0.75 mA 0.1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 2 mA 0.12 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA 2.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 5 mA |
Fluke 5522A Multifunction Calibrator |
AC Current – Generate1
Clamp Only |
(20.5 to 500) A
(45 to 440) Hz |
1.8 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | Coil / Fluke 5522A Multifunction Calibrator |
Version 004 Issued: November 10, 2017 www.anab.org
Page 5 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
AC Current – Measure1 | Up to 100 µA
(10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz |
0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA
0.16 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA 0.07 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.03 pA |
Agilent 3458A/002
Precision Multimeter |
AC Current – Measure1 | (0.1 to 100) mA
(10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz |
0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA
0.16 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.07 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.04 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 μA 0.08 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 20 µA 0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 40 µA 0.56 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 150 µA 0.41 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.17 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.09 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.11 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 0.31 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.2 mA 1 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.4 mA |
Agilent 3458A/002
Precision Multimeter |
Resistance – Generate, Fixed Points1 | 1, 1.9 Ω
10, 19 Ω 100, 190 Ω 1, 1.9 kΩ 10, 19 kΩ 100, 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ |
98 μΩ/Ω
23 μΩ/Ω 10 μΩ/Ω 6.5 μΩ/Ω 6.5 μΩ/Ω 8.5 μΩ/Ω 13 μΩ/Ω 18 μΩ/Ω 40 μΩ/Ω 48 μΩ/Ω 0.1 mΩ/Ω |
Fluke 5730A/03
Multifunction Calibrator |
Version 004 Issued: November 10, 2017 www.anab.org
Page 6 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Resistance – Generate1 | Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω
330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 330 MΩ to 1.1 GΩ |
40 μΩ/Ω + 0.01 Ω
30 μΩ/Ω + 0.015 Ω 28 μΩ/Ω + 0.015 Ω 28 μΩ/Ω + 0.02 Ω 29 μΩ/Ω + 0.02 Ω 29 μΩ/Ω + 0.2 Ω 29 μΩ/Ω + 0.1 Ω 29 μΩ/Ω + 1 Ω 29 μΩ/Ω + 1 Ω 33 μΩ/Ω + 10 Ω 33 μΩ/Ω + 10 Ω 60 μΩ/Ω + 150 Ω 0.013 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.25 kΩ 0.025 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 2.5 kΩ 0.05 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3.0 kΩ 0.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 100 kΩ 1.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 500 kΩ |
Fluke 5522A Multifunction Calibrator |
Resistance – Measure1
Fixed Points |
Up to 10 Ω
(10 to 100) Ω 100 Ω to 100 kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ |
16 μΩ/Ω + 50 µΩ
14 μΩ/Ω + 0.5 mΩ 12 μΩ/Ω + 5 mΩ 16 μΩ/Ω + 2 Ω 50 μΩ/Ω + 100 Ω 0.05{3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 1 kΩ 9.2 μΩ/Ω + 1 Ω |
Agilent 3458A/002
Precision Multimeter |
Capacitance – Generate1 | (0.19 to 0.1099) nF (1.1 to 3.299) nF (3.3 to 329.999) nF
(0.33 to 1.09999) µF (1.1 to 3.29999) µF (3.3 to 10.9999) µF (11 to 32.999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.09999) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF |
1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 nF
1.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.01 nF 0.39 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.3 nF 0.38 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 nF 0.37 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 nF 0.38 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 nF 0.53 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 30 nF 0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 µF 0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.3 µF 0.57 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 1 µF 0.58 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 3 µF 0.59 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 10 µF 0.65 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 30 µF 1.3 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mF |
Fluke 5522A Multifunction Calibrator |
Version 004 Issued: November 10, 2017 www.anab.org
Page 7 of 12
Electrical – DC/Low Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Oscilloscope Calibration – Vertical Deflection1
50 Ω, 1 kHz square wave 1 MΩ, 1 kHz square wave Flatness – Leveled Sine Wave Bandwidth Rise Time Time Interval2 |
1 mV to 6.6 V
1 mV to 130 V 5 mV to 5.5 V 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1 100) MHz <300 ps 1 ns to 20 ms 50 ms to 5 s |
0.59 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 40 µV
0.44 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 40 µV 2.5 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV 2.2 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV 4.6 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV 6.4 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading + 0.1 mV + 13 ps / -110 ps 3 μs/s (26 + 1 000t) μs/s |
Fluke 5522A/SC1100
Multifunction Calibrator |
Power Meter Range
Calibration1 |
3 μW to 100 mW | 0.25 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443} of reading | HP 11683A Power Meter Calibrator |
Electrical Calibration of Thermocouple Indicating Devices1 – | Type B
(600 to 1 820) °C Type C (0 to 2 316) °C Type E (-250 to 1 000) °C Type J (-210 to 1 200) °C Type K (-200 to 1 372) °C Type L (-200 to 900) °C Type N (-200 to 1 300) °C Type R (0 to 1 767) °C Type S (0 to 1 767) °C |
0.41 °C
0.38 °C 0.29 °C 0.19 °C 0.21 °C 0.12 °C 0.26 °C 0.45 °C 0.44 °C |
Fluke 7526A Process Calibrator |
Thermodynamic
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Relative Humidity – Measure | (0 to 90) {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}RH | 1.7 {3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}RH | Vaisala MI70 / HMP75
Thermohygrometer |
Temperature – Measuring Equipment1 | (-25 to 350) °C | 0.12 °C | Hart 1502A with 5616 PRT
and dry block |
Temperature – Measure1 | (-25 to 600) °C | 0.025 °C | Hart 1502A with 5616 PRT |
IR Thermometry1 | (20 to 100) ºC (100 to 300) ºC (300 to 500) ºC | 0.51 ºC
0.61 ºC 0.8 ºC |
Fluke 9132 Blackbody
ε = 0.95, λ= (8 to 14) μm |
Time and Frequency
Parameter/Equipment | Range | Expanded Uncertainty of
Measurement (+/-) |
Reference Standard, Method, and/or Equipment |
Frequency – Measure | 10 MHz | 1 x 10-11 Hz/Hz | HP 58503A/B GPS |
Frequency – Measure1 | 10 Hz to 26.5 GHz | 1 x 10-8 Hz/Hz | HP 53131A Counter, Agilent E4440A Spectrum Analyzer |
Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95{3abc3950d4f1f8f388f3ff046375d7d82c013b00bce2a30b1200ecdfc3f73443}.
Notes:
1. On-site calibration service is available for this parameter, since on-site conditions are typically more variable than those in the laboratory, larger measurement uncertainties are expected on-site than what is reported on the accredited scope
2. L = length in inches, t = time in seconds, D = diameter in inches, R = resolution of the device under test
3. This scope is formatted as part of a single document including Certificate of Accreditation No. AC-2080.08.
Version 004 Issued: November 10, 2017 www.anab.org